An outdoor multifunctional integrated distribution cabinet for metering, outgoing circuits and reactive power compensation.
Progettato per sistemi di distribuzione elettrica che richiedono un funzionamento stabile, una protezione del circuito trasparente e un'installazione pratica per progetti industriali, commerciali, di servizi pubblici e infrastrutturali.
Dongfang Electric Power (Shandong) Co., Ltd. supporta la selezione dei prodotti in base al livello di tensione, alla corrente nominale, all'ambiente di installazione, alla struttura dell'armadio, al metodo di connessione dei cavi e alle esigenze di documentazione del progetto.
Application Scope
The JP series outdoor multifunctional integrated distribution cabinet is an outdoor integrated distribution device combining metering, outgoing circuits, reactive power compensation and other functions. It has short-circuit, overload, overvoltage and leakage protection functions. It is compact, attractive in appearance, economical and practical. It is installed on the pole of an outdoor pole-mounted transformer and is a new-generation ideal distribution product for urban and rural power grid reconstruction.
Significato del Modello
| JP | Box-type metering distribution device |
|---|---|
| Transformer Capacity | Transformer capacity code |
| Outgoing Circuits | Number of outgoing circuits |
Usa Condizioni Ambiente
Main Technical Parameters
| No. | Nome | Unit | Parameter |
|---|---|---|---|
| 1 | Transformer Capacity | kVA | 30 to 400 |
| 2 | Rated Operating Voltage | V | AC400 |
| 3 | Auxiliary Circuit Operating Voltage | V | AC220, AC380 |
| 4 | Rated Frequency | Hz | 50 |
| 5 | Rated Current | A | Not more than 630 |
| 6 | Rated Leakage Operating Current | A | 30 to 300, adjustable |
| 7 | Protection Grade | IP44 |
Main Circuit Scheme Diagram
Knife switches or knife-fuse switches can use HD11F, HR5, HR6 and other series. Fuses can use D220, CMI, NS, C45, D247 and other series. AC contactors can use CJ20, B series, CJX2, CJ19 and other series. Zero-sequence current transformer leakage relays can use JD, LLJ and other series. Current transformers can use LM21-0.5, LMK-0.66 and other series. Surge arresters can use FYS, Y3W and other series. Capacitors can use BSMJ, BCMJ and other series. Automatic compensation controllers can use JKI, JKG and other series.
The compensation circuit can be selected from 1 to 4 circuits, and each circuit capacity can be selected from 3 to 20kvar. According to customer needs, temperature and humidity control devices can be installed in the box. The compensation circuit switching form can also be selected according to user requirements, such as contactless module switching or load-switch switching.
Cabinet Structure Diagram
The product uses a horizontal box structure. The enclosure dimensions and layout are selected according to the project configuration.
I prodotti vengono selezionati per una distribuzione, protezione, commutazione e controllo affidabili nei pratici sistemi di alimentazione.
L'attrezzatura può essere abbinata al livello di tensione, alla capacità, alla struttura dell'armadio, all'ingresso del cavo e all'ambiente di installazione.
Documenti tecnici, disegni, etichette, imballaggio e requisiti di consegna possono essere coordinati per l'uso del progetto.

Dongfang Electric Power (Shandong) Co., Ltd. si concentra su apparecchiature di distribuzione di energia orientate al progetto, tra cui scatole di distribuzione, armadi di distribuzione, quadri estraibili, unità principali ad anello, scatole di diramazione per cavi, armadi di compensazione, sistemi di misurazione, sistemi busway e cavi di alimentazione.
Esamina i modelli di prodotto in base a tensione, capacità, quantità di alimentatore e ambiente di installazione.
Coordina disegni, parametri tecnici, etichette, dettagli di imballaggio e documenti di consegna.
Comunicaci il nome del prodotto, il livello di tensione, la capacità di carico, la quantità, il sito di installazione e i requisiti di consegna Il nostro team aiuterà a verificare la configurazione del prodotto adatto.