A fixed AC low voltage power distribution cabinet for power conversion, distribution and control in AC 380V systems.
Conçu pour les systèmes de distribution électrique qui nécessitent un fonctionnement stable, une protection par circuit transparent et une installation pratique pour les projets industriels, commerciaux, utilitaires et d'infrastructure.
Dongfang Electric Power (Shandong) Co., Ltd. prend en charge la sélection de produits par niveau de tension, courant nominal, environnement d'installation, structure d'armoire, méthode de connexion par câble et besoins en documentation de projet.
Produit Application
The GGD type AC low voltage power distribution cabinet is suitable for power users such as power plants, substations, factories and mining enterprises. It is used in AC 50Hz distribution systems with rated operating voltage of 380V and rated operating current up to 3150A for power conversion, distribution and control of power, lighting and distribution equipment.
The GGD cabinet was designed according to requirements from the competent energy authority, broad power users and design departments, based on principles of safety, economy, rationality and reliability. It has high breaking capacity, good dynamic and thermal stability, flexible electrical schemes, convenient combination, strong serialization and practicality, novel structure and high protection grade. It is an updated product for low-voltage complete switchgear. It complies with IEC439 Low-Voltage Switchgear and Controlgear and GB7251 Low-Voltage Complete Switchgear standards.
Utiliser les conditions environnementales
Model Meaning
| G | AC low-voltage distribution cabinet |
|---|---|
| G | Fixed installation and fixed wiring of electrical components |
| D | Power cabinet |
| Design Sequence | 1: breaking capacity 15kA; 2: breaking capacity 30kA; 3: breaking capacity 50kA |
| Main / Auxiliary Circuit Scheme | Main circuit scheme code and auxiliary circuit scheme code |
Electrical Performance – Technical Parameters
| Model | Tension nominale | Courant évalué | Rated Short-Circuit Breaking Current | Résistance à court terme évaluée actuelle | Courant de support de pointe évalué |
|---|---|---|---|---|---|
| GGD1 A | 380V | 1000A | 15kA | 15kA | 30kA |
| GGD1 B | 380V | 600A (360A) | 15kA | 15kA | 30kA |
| GGD1 C | 380V | 400A | 15kA | 15kA | 30kA |
| GGD2 A | 380V | 1500A (1600A) | 30kA | 30kA | 63kA |
| GGD2 B | 380V | 1000A | 30kA | 30kA | 63kA |
| GGD3 A | 380V | 3150A | 50kA | 50kA | 105kA |
| GGD3 B | 380V | 2500A | 50kA | 50kA | 105kA |
| GGD3 C | 380V | 2000A | 50kA | 50kA | 105kA |
Main Circuit Scheme
The main circuit of the GGD cabinet is designed with 129 schemes and 298 specifications, excluding derivative schemes and specifications caused by auxiliary circuit function changes and control voltage changes. GGD1 has 49 schemes and 123 specifications; GGD2 has 50 schemes and 107 specifications; GGD3 has 27 schemes and 68 specifications. The main circuit schemes were selected after consulting design and user departments and include schemes required by power plants. Rated current is increased to 3150A, suitable for distribution transformers of 2000kVA and below. In addition, GGJ1 and GGJ2 capacitor compensation cabinets are designed for reactive power compensation, with 4 main circuit schemes and 12 specifications.
Les produits sont sélectionnés pour une distribution, une protection, une commutation et un contrôle fiables dans des systèmes électriques pratiques.
L'équipement peut être adapté au niveau de tension, à la capacité, à la structure de l'armoire, à l'entrée du câble et à l'environnement d'installation.
Les documents techniques, les dessins, les étiquettes, les exigences d'emballage et de livraison peuvent être coordonnés pour une utilisation dans le cadre d'un projet.

Dongfang Electric Power (Shandong) Co., Ltd. se concentre sur les équipements de distribution d'énergie orientés projet, y compris les boîtes de distribution, les armoires de distribution, les appareillages de commutation retirables, les unités principales annulaires, les boîtes de dérivation de câbles, les armoires de compensation, les systèmes de mesure, les systèmes de busway et les câbles électriques.
Examinez les modèles de produits en fonction de la tension, de la capacité, de la quantité de chargeur et de l'environnement d'installation.
Coordonner les dessins, les paramètres techniques, les étiquettes, les détails d'emballage et les documents de remise.
Dites-nous le nom du produit, le niveau de tension, la capacité de charge, la quantité, le site d'installation et les exigences de livraison Notre équipe vous aidera à vérifier la configuration appropriée du produit.